17
2.75" (70mm)
4.50" (114mm)
2.204" (56mm)
2.834" (72mm)
Parameter Value Comment
Annunciator Volume 105 dB SPL Mechanical Volume Control
Annunciator Frequency 2.9 kHZ
Standard Comment
NMEA 2000
®
Standard Level A
Maritime Navigation and Radio Communication Equipment & Systems IEC 61162-3
Maritime Navigation and Radio Communication Equipment & Systems IEC 60945
FCC and CE mark Electromagnetic Compatibility
Description PGN # PGN Name Default Rate
Periodic Data PGNs 128720 Proprietary Alarm Status* 1 time/second
Response to Requested PGNs
126464 PGN List (Transmit and Receive) N/A
126996 Product Information N/A
126998 Configuration Information N/A
Protocol PGNs
059392 ISO Acknowledge N/A
059904 ISO Request N/A
060928 ISO Address Claim N/A
065240 ISO Address Command N/A
126208 NMEA N/A
Maretron Proprietary PGNs 128720 Configuration N/A
Parameter Value Comment
Operating Voltage 9 to 32 Volts DC Voltage
Power Consumption
100 mA NMEA 2000 Interface
Load Equivalence Number (LEN)
2 NMEA 2000® Spec. (1LEN = 50 mA)
Reverse Battery Protection Yes Indefinitely
Load Dump Protection Yes Energy Rated per SAE J1113
Parameter Value Comment
Size 2.75” x 4.50” x 2.00” (70mm x 114mm x 51mm)
Including wall plate – Mounts in standard single-gang electrical box
Weight 13 oz. (368.5g)
Parameter Value
IEC 60945 Classification Exposed
Degree of Protection IP67
Operating Temperature -25°C to 55°C
Storage Temperature -40°C to 70°C
Relative Humidity 93%RH @40° per IEC60945-8.2
Vibration 2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s
2
per IEC 60945-8.7
Rain and Spray 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8?
Solar Radiation Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10
Corrosion (Salt Mist) 4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12
Electromagnetic Emission Conducted and Radiated Emission per IEC 60945-9
Electromagnetic Immunity Conducted, Radiated, Supply, and ESD per IEC 60945-10
Safety Precautions Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Environmental Mechanical
Electrical
NMEA 2000
®
Parameter
Group Numbers (PGNs)
Certifications
Specifications
*Future firmware updates will allow the ALM100 to be in conformance with the
upcoming NMEA 2000 alarm messaging protocol, once it is defined.