any of the sources by that amount ensures that none of the sources may be
overloaded.
Breakers that are Locked will not be considered for restoring.
Only breakers that have been turned off previously by N2KView because of Load
Shedding will be considered for restoration. The Breaker Status reported in the
Load Shedding Dialog will be “Load Shed”.
If any source has a Load Shedding Current programmed (i.e. the source is
known be in use), and the current reported by that source is not available
(displayed as a dash) NO loads will be restored.
When load shedding is disabled, all loads that have been shed will be restored.
Revision 4.0.2 Page 352