Maretron Alarm Module ALM100 Uživatelský manuál Strana 248

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 380
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 247
User 1This selection sets the vessel’s operating mode to “User 1”. All alerts
which are enabled in “User 1” mode will be enabled. All other alerts will be
disabled.
User 2This selection sets the vessel’s operating mode to “User 2”. All alerts
which are enabled in “User 2” mode will be enabled. All other alerts will be
disabled.
Changing the Operating Mode may disable a number of alerts. If any alerts are
Active or Awaiting Cancel they will remain Active or Awaiting Cancel until
acknowledged by the user, when they will be disabled if they are disabled in the
new operating mode. Alerts that have been Accepted (i.e. the condition causing
the alert is still present) will be disabled immediately if they are disabled in the
new operating mode.
Remote Alerts Play Computer Sound When Alerts are received from another
N2KView or DSM250 Alert Source, the computer sound will beep while the Alert
is in the Active state if this box is checked
Only show alerts active in the chosen mode If this is checked, then the
alerts shown in the Alerts Table will be limited to those active in the chosen
Operating Mode.
Alerts TableThis table lists all the alerts defined in this instance of N2KView.
Clicking on a row in the table will select an alert for editing or deletion. Double
clicking on a row in the table will open the Alert Edit Dialog for that alert.
The Annunc and Email columns give a quick overview of which alerts are
configured to send emails and sound annunciators in the current operating mode.
NewClick this button to create a new alert. A dialog will appear allowing you to
select a parameter and alert class, and the appropriate Alert Editor dialog will
appear, letting you configure the new alert.
EditClicking this button causes the Alert Editor dialog to appear for the
selected alert.
DeleteClicking this button causes the selected alert to be permanently deleted.
A warning dialog is displayed. Pressing the Delete button on the keyboard will
have the same effect.
SaveClicking this button causes the new Alert Operating Mode to be Set and
then Alerts Setup Dialog to be closed.
Cancel Clicking this button causes the Alerts Setup Dialog to be closed without
changing the Alert Operating Mode.
Revision 4.0.2 Page 248