FFM100 User’s Manual
Page 10 Revision 1.3
Fluid flow sensor 0 power connection
Fluid flow sensor 0 ground connection
Fluid flow sensor 0 phase A connection
Fluid flow sensor 0 phase B connection
Fluid flow sensor 0 phase C connection
Fluid flow sensor 0 temperature sensor connection
Fluid flow sensor 1 power connection
Fluid flow sensor 1 ground connection
Fluid flow sensor 1 phase A connection
Fluid flow sensor 1 phase B connection
Fluid flow sensor 1 phase C connection
Fluid flow sensor 1 temperature sensor connection
Table 1 - Fluid Flow Sensor Connections
For differential mode, Channel 0 must be connected to the fuel flow sensor on the supply fuel
line, and Channel 1 must be connected to the fuel flow sensor on the return fuel line.
Please refer to Figure 6 for connecting the FFM100 to a M1RSP-2R-E8, M2RSP-2R-E8, or
M4ARP-2-E8 fluid flow sensor. This figure shows the connection of the fluid flow sensor to
channel 0. Connections to other channels are similar.
Figure 6 – Fluid flow sensor Connection Diagram
2.5.2 NMEA 2000
®
Connection
The NMEA 2000
®
connector can be found on the side of the enclosure. The NMEA 2000
®
connector is a round five pin male connector (see Figure 7). You connect the FFM100 to an
NMEA 2000
®
network using a Maretron NMEA 2000
®
cable (or an NMEA 2000
®
compatible
cable) by connecting the female end of the cable to the FFM100 (note the key on the male
connector and keyway on the female connector). Be sure the cable is connected securely and